The
operating principle of the newly developed fluid inclination sensors
from 2E, is based on the inclination dependent changes of a
difference capacity. Using the two halves of the housing and a spacer
disc a cylindrical cavity can be formed that is half-filled with a
dielectric fluid. Two semi-circular electrodes are housed on the
front side and on the other side there is a circular electrode. By
inclining the measuring cell horizontally the dielectric fluid can
maintain its position as a result of the gravitation. The capacitor
changes depending on the angle of inclination between the electrode
pairs which can be electronically recorded and evaluated.
|